Support Data Collector
What is it?
The Support Data Collector is an LSAM procedure that gathers OS 2200 diagnostic data for incidents reported to SMA Support. The Data Collector creates a text data file containing:
- Log files
- Installation parameters
- Program versions
- TIP file contents
- Operating system information
- Installed program information
- Current contents of the Common Data Bank (CDB)
- Tables of contents of the primary LSAM files (
*SKDPRGand*ABS)
After collecting the data, send to SMA Support for further analysis.
Requirements
The Support Data Collector procedure requires the following information and capabilities:
- The date of the reported incident.
- When the date of the incident is the current day, and the OS 2200 LSAM runs are processing; issue BRKPT commands to each of the runs to cycle the log files.
:::tip Example
@@CONS *XFRTCP BRKPT
@@CONS *LSAM BRKPT
@@CONS *LMAM BRKPT
:::
- The Data Collector collects the XFRTCP, LSAM, and LMAM log files (
BKXFRTCP,BKLSAM, andBKLMAM), plus the MAPPER MAM log files when you choose to include MAM data. Log files of other modules, such as JORS, are not collected. - When one or more of the modules are not in use at your site, skip the BRKPT command for that module.
:::info Note
The console keyin (*module) may be different at your site. Use the appropriate keyin for each module.
:::
- The approximate time of the incident.
- ASCII file transfer capability on the OS 2200 to send SMA the data.
Initiate the Support Data Collector Procedure
Supply the Incident Time and Date
-
From a DEMAND session, set the LSAM file qualifier: @QUAL [LSAMqualifier]
-
Provide the incident date and incident time to the Data Collector:
@ADD *SKDPRG.SUPPORT/ECL -
At the
Enter date of incident (yyyymmdd) <today>prompt, enter the date of the reported incident. To accept the displayed default of today's date, simply transmit. -
At the
Enter approximate time of incident (hhmm) <0001>prompt, enter the approximate time of the reported incident. The procedure selects log files that were active at this time. To accept the displayed default of one minute past midnight, simply Transmit. -
When MAPPER MAM is installed, the procedure prompts
Include MAPPER Mam data? (Y/<N>). EnterYto include MAM data, or transmit to accept the default ofN. -
When you enter
Y, at theEnter the Mam Site(s) to include (i.e. 1,2,A,3)prompt, enter the MAM sites to include, separated by commas.
:::info Note
To stop the procedure without collecting data, enter @EOF in response to any prompt.
:::
Review Information
- The procedure displays helpful information, as well as suggestions for additional information that the Data Collector was unable to retrieve.
- The procedure then displays the location of the generated Data Collector runstream (e.g.,
*SKDPRG.SUPP/ECL). - The procedure provides the ECL statements to either
@ADDor@STARTthe data collection. It also provides the file name with the collected data. - The procedure displays the file name of the collected data:
[LSAMqualifier]*SUPPyyyymmdd, whereyyyymmddis the date you run the setup procedure (not the incident date). - The procedure finally displays the "END SUPPORT DATA COLLECTOR SETUP." message.
Start Data Collection
To collect the LSAM data, issue one of the displayed ECL commands:
@ADD *SKDPRG.SUPP/ECL
- or -
@START *SKDPRG.SUPP/ECL
:::info Note
The Data Collector may require up to 20 minutes to create the data file.
:::
Send the Data File to SMA
Following the data collection process, send the data file (*SUPPyyyymmdd) to SMA with a description of the incident. The following are viable methods for sending the collected data to SMA:
- Transferring the file to a platform where it may be attached to an email. Transfer the file in ASCII format. Depending on the size of the file, it may be useful to compress the file before emailing it.
- Emailing the file directly, as an ASCII text file, from the OS 2200 using Enterprise Output Manager (EOM [formerly known as Depcon]).
- Transferring the file, using ASCII format, to SMA's ftp site. Contact SMA with the incident details and the name of the ftp'd file.
:::info Note
If necessary, contact SMA Support for assistance with this procedure.
:::
Frequently Asked Questions
How long does the data collection take?
The Data Collector procedure may require up to 20 minutes to create the data file.
What data does the Support Data Collector gather?
The collector creates a text file containing log files, installation parameters, program versions, TIP file contents, operating system information, installed program information, the current contents of the CDB, and tables of contents of the *SKDPRG and *ABS files.
What format should I use when sending the data file to SMA?
Always transfer or send the data file in ASCII format. For large files, compressing the file before sending is recommended.
What if one of the LSAM modules (XFRTCP, LSAM, LMAM) is not in use at my site?
Skip the BRKPT command for any module that is not in use. Only issue BRKPT for the modules that are actively running at your site.